Overview
The FUYL Lock Modules are specifically designed to be user replaceable at the request of our support team. The following guide assumes no speciality skills, though you will need a Torx T20 screw driver or bit and the locker's security keys (we provide both in the accessories kit).
Procedure
Get access
- Unplug the locker Safety first!
- Open the side door Using the security key.
- Open the bays Identify which bank of 5 bays (1–5, 6–10, 11–15) the replacement belongs to, and open all 5 bays with their manual release pins.
- Clear the outlets Check for and remove any cables or devices connected to the GPOs (outlets/plugs) in these bays.
- Move the PDU Remove the three thumb-screws from the PDU block behind the cleared bays, and carefully slide the PDU backwards and away for better access to the locks.
Replace the lock module
- Disconnect the lock module Remove all cables connected to it. Release connectors with fastening clips correctly: squeeze the clip and pull from the connector, not the cabling.
- Unscrew the lock module Remove the three screws holding it from inside the bay with the T20 screwdriver, supporting the module so it doesn’t fall loose.
- Swap the lock module Remove it and replace it with the new unit.
- Replace the three screws
Reassemble
- Reconnect the cables Reconnect all data and power cables to the new lock module. Follow the arrangement of the other lock modules for orientation, and make sure any clips are securely fastened again.
- Replace the PDU Gently tighten its thumb-screws.
- Close up and power on Close and lock the side door, and reconnect power to the locker.
- Address the locks if needed If there are inconsistencies after the locker boots up (LEDs cycling RGB or incorrect lock numbers), perform "Address Locks" from the Danger zone section of the admin menu.
Contact support if you encounter any issues with this process.