Overview
This article covers replacing the 12V power supply (PSU) in a FUYL Tower (MK2).
Procedure
- Power down the locker Unplug it and wait 30 seconds for any power to dissipate.
- Open the Side Access Panel
- Unplug the mains cable Check the Mains Power Cable is unplugged from the top of the 12V PSU.
- Disconnect the 12V PSU Unplug it from the 12V Distribution Cable, then thread it back out through the grommets.
- Undo the clamping bracket Undo the screw at the bottom of the bracket with the Torx screwdriver.
- Remove the 12V PSU Slide the clamping bracket up and lift it off, then rotate the PSU out of the bracket.
- Fit the replacement Reverse steps 3 to 6, with the PSU’s indicator light facing outwards. Make sure connections are firm, and that cables on the Control Door shelf don’t stop the door opening or closing.