Overview
If you encounter a fault with the lock in the FUYL™ Locker Mk1 the process for removing and replacing that lock is more complicated than with our newer lockers. With just a torx and phillips head screwdriver you can access and remove the locks.
Process
- Power down the locker Make sure the power to the locker is turned off.
- Remove the side panel Undo the security screws holding it in place, about 15 of them.
- Find the lock The silver locks are screwed into the chassis.
- Free the cables Follow the wiring from the lock to the control board, then cut the right cable tie. Take your time, as the wiring can be hard to follow.
- Unscrew the lock Undo the screws holding it in place.
- Unplug the cables Disconnect the two cables joining the lock to the locker.
- Fit the new lock Plug the cables into the new lock and screw it into place. Add cable ties for neatness if needed, then refit the side panel and its screws.
If you have any more questions, please don’t hesitate to contact us.