Overview
In rare cases, some MK3 locks may experience the manual release pin or lever getting stuck on the edge of the lock component's metal casing. This issue has been addressed at the factory and communicated to the lock supplier. However, if existing customers encounter this issue, we now offer a solution.
The Issue
The manual release pin can be accessed when the FUYL™ Locker's side door is open and is located on each lock module.
Below is an image showing the electronic lock removed from the module, with the pin stuck down.
The pin is essentially a screw:
Temporary Fix (No extra hardware)
We do not recommend applying this fix unless our end-caps are unavailable, but include instructions here to illustrate what measures may need to be reversed when installing the permanent fix.
Prerequisites
- FUYL Locker keys (KA6 - supplied with the Locker)
- Philips head screwdriver
Procedure
- Power down the locker Leave it for 30 seconds for power to dissipate. As well as a precaution, this stops bay status changing during the process.
- Open the side of the locker You may need to maneuver it for proper access.
-
Move the PDU Each bank of 5 bays has a Power Distribution Unit (PDU) that needs moving for access to the locks. Unscrew its 3 thumbscrews and slide it towards the back of the locker.
- Unscrew the pin By about 1–2 turns. This increases the clearance between the pin and the lock’s edge, preventing it from getting stuck.
- Reassemble and test Reassemble the locker and test it.
Permanent Fix (With Supplied Caps)
While this fix could be applied only to the locks where the issue has been observed, it could be applied to more bays as a precaution (should stock be available).
Prerequisites
- FUYL Locker keys (KA6 - supplied with the Locker)
- 4mm PVC end caps (Matching the number of bays to install)
- Long-Nose Pliers or large tweezers (recommended)
- Philips head screwdriver (if the quick fix has been applied previously)
- Admin PIN or RFID (Locker administrator can provide these)
Process
Fit the end caps
- Power off the locker Wait 30 seconds so power dissipates completely. This stops bay status changing during the process.
- Open the side of the locker You may need to maneuver it for proper access.
-
Access the lock modules Each bank of 5 bays has a Power Distribution Unit (PDU) that needs moving for access to the locks. Unscrew its 3 thumbscrews and slide it towards the back of the locker.
- Reverse the quick fix If it was applied, tighten the screw with a Phillips head screwdriver.
-
Install the PVC end caps Use pliers or tweezers to slide an end cap over each pin. The pin may move, which is expected. Approaching from the underside of the pin may help.
-
Check each cap Press it so it entirely covers the pin.
Test the locks
- Test the manual release Once all PVC end caps are installed, close all bays, then activate each manual release lever in turn to check the bays open. Close all bays afterward.
- Power on the locker
- Test the locks electronically In the Admin menu on the locker, go to "Bay Access" and select "Unlock All Bays". Check every bay opens.
- Close all bays