Overview
This article explains how heat is generated and managed in FUYL Lockers, and how to place and use your locker so it stays cool. Where cooling features differ between models, the differences are noted below. If you're not sure which locker you have, see Identify a Smart Locker.
Heat generation and cooling
Some warmth is expected when devices are charging. The amount of heat generated depends on the device model, its charging requirements, and whether it is asleep or actively running tasks. Room temperature and the number of devices charging at the same time can also influence the overall heat load.
How the locker manages heat
The locker manages heat in three ways:
- Quiet fans cool the locker's internal electronics. Power supply fans are fitted to all MK3 and MK4 lockers (except the 5-door MK3).
- Devices in the bays are passively cooled, with ventilation holes allowing heat to escape. Keeping these openings clear helps heat dissipate.
- Lock modules include over-temperature protection. If a module becomes too hot, it shuts down until it has cooled sufficiently. Once the module has cooled, unplug the device and plug it back in to resume charging.
These features help manage heat, but do not replace the need for suitable placement, unobstructed ventilation, and sensible device use.
Device charging protection: Many USB-C devices also have built-in thermal management that automatically reduces charging speed if the device or battery becomes too warm.
Older FUYL Lockers (MK1, MK2 & MK2.5)
Earlier FUYL Lockers are passively cooled in the same way, so the ventilation and placement guidance below applies to them just as much. Their USB-A charging ports are limited to 5V 2.4A, so almost all of the heat in these lockers comes from the devices themselves, or from a device's own charger if it's plugged into the bay's power outlet (GPO).
Recommended use and placement
We recommend putting devices into sleep mode before storing them to reduce power consumption and heat generation.
For effective airflow:
- Position the locker in a cool, dry, well-ventilated location, away from direct sunlight, heaters, and other significant heat sources.
- Allow sufficient clearance around the locker so ventilation openings and airflow paths remain unobstructed.
- Avoid installing the locker in a recess or enclosed space that restricts airflow. Trapped warm air can reduce cooling performance and lead to higher operating temperatures.
- Keep ventilation openings clear of stored items, packaging, and surrounding furniture. Do not cover the locker or use its ventilation openings as storage areas.
- Keep each device's own ventilation openings unobstructed by other items in the bay.
The surrounding space should allow warm air to disperse, rather than accumulate around the locker.
Installation guidance is covered in FUYL Physical Installation.
Cooling features by model
| Feature / Locker | FUYL 8 & FUYL 23 (MK4) | FUYL Tower Pro (MK3) |
|---|---|---|
| Power supply fans | Yes | Yes (except 5-door models) |
| Passive bay ventilation | Yes | Yes |
| Lock module over-temperature protection | Yes | Yes |
| After over-temperature protection trips | Unplug and replug the device to resume | Unplug and replug the device to resume |
Still concerned?
If a locker feels hotter than you'd expect after checking the above, or bays regularly stop charging, please contact our support team with the locker's serial number, roughly how many devices were charging and which models, and where the locker is installed. A photo of the installation is a big help too.